145
Type AWBT-M/AWBT-M-E/AWBT-M-E-AC
221.C0
4
221.C0
6
221.C0
8
221.C1
0
221.C1
3
221.C1
6
Heating water
(secondary circuit)
Minimum flow rate
l/h
700
700
700
1400
1400
1400
Minimum volume in the heating system, can-
not be fitted with shut-off devices
l
50
50
50
50
50
50
Max. external pressure drop (RFH) at mini-
mum flow rate
mbar
705
705
705
500
500
500
kPa
70.5
70.5
70.5
50
50
50
Max. flow temperature
°C
60
60
60
60
60
60
Outdoor unit electrical values
Rated voltage, compressor
1/N/PE 230 V/50 Hz
Max. operating current, compressor
A
13.0
14.6
14.6
19.3
23.3
23.3
Starting current, compressor
A
15
15
15
15
15
15
Fuse rating
A
16
16
16
25
25
25
IP rating
IPX4
IPX4
IPX4
IPX4
IPX4
IPX4
Indoor unit electrical values
Heat pump control unit/PCB
■
Rated voltage, control unit/PCB
1/N/PE 230 V/50 Hz
■
Power supply fuse rating
1 x B16A
■
Internal fuse
6.3 A (slow)/250 V
Instantaneous heating water heater
■
Type AWBT-M-E/AWBT-M-E-AC:
Factory-fitted
■
Type AWBT-M:
Accessories
■
Rated voltage
1/N/PE 230 V/50 Hz
or
3/N/PE 400 V/50 Hz
■
Heating output
kW
9
■
Power supply fuse rating
3 x B16A
Max. power consumption
Fan
W
45
45
115
2 x 45
2 x 45
2 x 45
Outdoor unit
kW
2.85
3.20
3.30
4.36
5.08
5.08
Secondary pump (PWM)
W
60
60
60
60
60
60
Control unit/PCB, outdoor unit
W
15
15
15
15
15
15
Control unit/PCB, indoor unit
W
10
10
10
10
10
10
Control unit/PCB power, indoor unit
W
1000
1000
1000
1000
1000
1000
Refrigerant circuit
Refrigerant
R410A R410A R410A R410A R410A
R410A
■
Refrigerant charge
kg
1.80
1.80
2.39
3.60
3.60
3.60
■
Global warming potential (GWP)
2088
2088
2088
2088
2088
2088
■
CO
2
equivalent
t
3.8
3.8
< 5.0
7.5
7.5
7.5
■
Top-up charge for line lengths
>
12 m to
≤
30 m
g/m
20
20
60
33
33
33
Specification
Specification
(cont.)
51
17 700 GB
Appendix