138
Heating circuit 1
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
Standard room temperature
2000
200 (
≙
20 °C)
Reduced room temperature
2001
160 (
≙
16 °C)
Remote control
2003
0
Room temperature control
2005
0 Without remote
control
2 With remote con-
trol
Heating curve level
2006
0 (
≙
0 K)
Heating curve slope
2007
6 (
≙
0.6)
Influence room temperature hook-up
200A
10
Room temperature hook-up
200B
0
Max. flow temperature heating circuit
200E
550 (
≙
55 °C)
Runtime mixer heating circ
2015
Do not adjust.
Room temperature in party mode
2022
200 (
≙
20 °C)
Heating circuit 2
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
Standard room temperature
3000
200 (
≙
20 °C)
Reduced room temperature
3001
160 (
≙
16 °C)
Remote control
3003
0
Room temperature control
3005
0 Without remote
control
2 With remote con-
trol
Heating curve level
3006
0 (
≙
0 K)
Heating curve slope
3007
6 (
≙
0.6)
Influence room temperature hook-up
300A
10
Room temperature hook-up
300B
0
Max. flow temperature heating circuit
300E
550 (
≙
55 °C)
Runtime mixer heating circ
3015
Do not adjust.
Room temperature in party mode
3022
200 (
≙
20 °C)
Commissioning/service reports
Control parameter report
(cont.)