TM-VE414/415MC_25
REV_D
TM-VE414/415MC
/ Operating and Maintenance Instructions Manual
PIPE SIZE ADJUSTMENT
Rotate the timer dial to the appropriate pipe size.
•
2–6-inch/60.3–168.3-mm pipe sizes are
in the 12:00 position. Ensure that the timer
range is set to “SEC-10.”
•
8–12-inch/219.1–323.9-mm pipe sizes are
in the 2:00 position. Ensure that the timer
range is set to “SEC-50.”
GROOVE DIAMETER STOP ADJUSTMENT
The groove diameter stop shall be adjusted
for each pipe size or change in wall thickness.
The groove diameter, which is identified as the
“C” dimension, is listed under the “Roll Groove
Specifications” section. In addition, a label
affixed to the tool lists the “C” dimensions.
NOTICE
• To perform the following adjustments,
use several short, scrap sections of pipe
that are the proper material, diameter,
and thickness to be grooved. Ensure
that the scrap sections meet the length
requirements listed in Table 1.
To achieve the proper diameter:
1.
Determine the diameter and thickness of the
pipe to be grooved.
2.
Locate the proper diameter and thickness on
the pipe size indicator label of the depth stop.
The pipe size indicator barrel can be rotated for
ease of viewing.
3.
Unlock the groove diameter stop (clockwise)
from the depth adjuster. Align the top edge of
the depth adjuster with the lowest line position
of the proper size and schedule markings on
the indicator barrel. Hold the depth adjuster to
prevent it from turning.
4.
Turn the groove diameter stop counter-
clockwise to lock the depth adjuster in position.
Summary of Contents for VE414MC