5.
Pull the “EMERGENCY STOP” button and
confirm that power to the motor remains off.
Depressing the foot switch or adjusting the
selector switch should have no effect on the
state of the tool. All components should remain
off.
WARNING
• The motor must not re-energize until
after the “RESET” button has been
pressed.
• If the motor energizes after an emergency
stop without first being enabled,
discontinue use and contact Victaulic.
Failure to follow this instruction could result
in serious personal injury.
6.
Press the “RESET” button.
7.
Depress the safety foot switch, confirm tool
operation, then release the safety foot switch.
8a.
Turn the selector switch to the “NORMAL”
position. The tool head should lower when the
footswitch is depressed, and rise to its resting
position when the footswitch is released.
8b.
Turn the selector switch to the “JOG”
position. The tool head should lower when the
footswitch is depressed, and remain in position
when the footswitch is released.
8c.
Turning the selector switch from “JOG” to
“NORMAL” with the head in a lowered position
should cause the head to rise to its resting
position.
9.
If the tool does not function as described,
refer to the “Troubleshooting” section.