TM-VE414/415MC_39
REV_D
TM-VE414/415MC
/ Operating and Maintenance Instructions Manual
MAINTENANCE
DANGER
• Always turn off the
main power supply to
the tool before making
any tool adjustments or
before performing any
maintenance.
Failure to follow this instruction could result
in death or serious personal injury.
This section provides information about keeping
tools in proper operating condition and guidance
for making repairs when it becomes necessary.
Preventive maintenance during operation will
pay for itself in repair and operating savings.
Replacement parts shall be ordered from
Victaulic to ensure proper and safe operation of
the tool.
Before making any tool adjustments or before
performing maintenance on the tool, turn off the
main power supply (main circuit breaker panel,
knife switch, etc.). Lock the switch in the “OFF”
position to prevent accidental engagement.
NOTE:
Victaulic does not supply this lockout
mechanism.
LUBRICATION
1.
After every 8 hours of operation, lubricate the
tool.
Always lubricate the upper roll bearings
when rolls are changed.
1.
Lubricate the slide gibs at the two grease
fittings, as shown.
2.
Lubricate the upper roll bearing at the fitting,
as shown.
3.
Lubricate the main shaft bearings at the
fittings, as shown.