TM-VE414/415MC_7
REV_D
TM-VE414/415MC
/ Operating and Maintenance Instructions Manual
POWER REQUIREMENTS
DANGER
• ONLY QUALIFIED
ELECTRICIANS SHOULD
CONNECT INCOMING
POWER TO THE TOOL.
• To reduce the risk of electric shock,
check the electrical source for proper
grounding.
• Always turn off the main power supply
to the tool before making any tool
adjustments or before performing any
maintenance.
• DO NOT alter the plug in any way.
Failure to follow these instructions could
result in death or serious personal injury.
The VE414/415MC tool is designed to operate
on a 230/460-volt, 3-phase, 60-Hz power
supply or on a 380/400-volt, 3-phase, 50/60-Hz
power supply.
The tool is shipped with the wiring set for
230-volt operation, unless specified otherwise
on the order. To re-wire the tool for 460-volt
service, the following conversions shall be
made. Refer to the electrical schematic in the
RP-VE414/415MC Repair Parts List and the
information contained on the nameplate on the
tool’s drive motor and hydraulic pump motor.
All tool components are grounded to the tool
frame. Make sure the tool frame is properly
grounded.
For other voltages and frequencies, contact
Victaulic.
NOTE:
If the tool is ordered for
another voltage, no additional wiring is
necessary.
POWER HOOKUP
Each VE414/415MC tool is provided with a label
outside the main electrical enclosure, which
identifies voltage ratings for the tool (refer to
example below). Reference shall be made to
this label to ensure proper tool setup.
VOLTS
PHASE
HERTZ
FULL-LOAD CURRENT
SERIAL NO.
DATE MFD.
230
3
17.8 AMPS
60
• GEAR OIL – AGMA 7
• HYDRAULIC OIL – HIGH-PRESSURE, ANTI-WEAR ISO GRADE 32
• BEARING LUBE – ANTI-WEAR, EXTREME PRESSURE NLGI GRADE 2
VOLTS
PHASE
HERTZ
FULL-LOAD CURRENT
230
3
12.6 AMPS
60
DRIVE MOTOR:
SHORT CIRCUIT INTERRUPTING CAPACITY 5,000 AMPS
Victaulic Company World Headquarters
4901 Kesslersville Road • Easton, PA 18040
Manufactured in
Canada
victaulic.com
12934 Rev. A R512934LBL
ELECTRICAL
ASSEMBLY DWG.
R-740-414-SCH
REVISION LEVEL
VE414
460
3
8.9 AMPS
60
460
3
6.3 AMPS
60
DANGER
• ONLY QUALIFIED
ELECTRICIANS SHOULD
CONNECT INCOMING
POWER TO THE TOOL.
• The tool shall be grounded
properly.
Failure to follow these instructions could
result in death or serious personal injury.
The VE414MC tool is supplied with a #10/4 line
cord (3 power, 1 ground) and is set up for 230-
volt, 3-phase, 60-Hz power, unless specified
otherwise on the order.
If 460 volt is used, make sure the proper
conversions are made, which include: motor
connections, fuse changes, thermal overload
unit changes, and transformer connections.
Refer to the electrical wiring diagram on page
40 for complete information.
After power is connected, the tool shall be
checked for proper rotational direction.
Summary of Contents for VE414MC
Page 2: ......
Page 47: ...This page intentionally blank...