![Viavi CX300 ComXpert Operation Manual Download Page 229](http://html.mh-extra.com/html/viavi/cx300-comxpert/cx300-comxpert_operation-manual_1011808229.webp)
Chapter 7
Managing Files and Reports
Managing Files
22130634
CX300 ComXpert Operation Manual
Rev. 001
7.1.2 Using Save to Event Setup
Depending on the measurement mode, the test set can be configured to automatically
save measurement screen or result that falls outside the defined limit settings or when the
Fail indicator is on. The test set can also be configured to save the first event and pause
the measurement, or to save all the events continuously.
1.
Press the
Save
(
)
Button
.
2.
Press the
Folder
(
)
Button
to select the storage location.
3.
Select the
Save to Event Setup
box.
4.
Select the
File Name
input field and enter the file name using the on-screen
keyboard.
5.
Select to select the
File Type
from the following options:
Result
,
Result as CSV
,
and
Screen
.
6.
Select to switch the
Save On Event
to
On
or
Off
.
If the Save On Event is On, it is
saved with the selected file type in accordance with limit(s) fail.
7.
Select to switch the
Save Then Stop
to
On
to save the first event that fails
outside the limit(s) and to hold the measurement. Otherwise, leave this feature
off to save events continuously.
8.
Optional:
Select to switch the
Color Inversions
to
On
to invert the image color.
9.
Press the
Save Button
to save the file.
7.1.3 Using Quick Save Setup
The following procedure describes using the Quick Save Setup.
You can save your configured settings by using this Quick Save Setup feature.
1.
Press the
Quick Save Setup
box.
2.
Select the
File Name
input field and enter the file name using the on-screen
keyboard.
3.
Select to select the
File Type
from the following options:
Result
,
Report
,
and
Screen
.
If the file type is not selected, it is saved as a Screen type.
4.
Press the
Apply
button to apply the settings.