© Vestamatic GmbH
Subject to modifications!
- 21 -
Art.
-N
r.:
84
50
060
1
K
1•
V
est
amatic G
m
bH • Do
hr
w
eg
27 •
D
-41
066 M
önc
he
ngladb
ach •
www.v
est
amatic.
co
m
Information for the installer – Control box
Terminals
The temperature sensor TS Pro XL is connected at the control box to the terminals TS 01 and +12V.
The temperature sensor TE Indoor / TE Outdoor is connected via the internal terminals 1 and 2 to the
terminals thermostat and GND at the control box.
The polarity of the temperature sensor is not important for connection.
Figure:
Connection of TS Pro XL
Figure:
Connection of TE Indoor / TE Outdoor
Assembly / Connection of DCF radio-controlled clock receiver
Operation
The DCF Receiver picks up the time signal from the transmitter located in Mainflingen near Frankfurt.
This long-wave transmitter has an average range of 1500 km. Once received, the signal is decoded and
the control's internal clock is updated, resulting in a high degree of accuracy.
Choice of assembly location
The DCF Receiver must be mounted outdoors with the cable inlet at the bottom. Aligning the radio-
controlled receiver with Frankfurt will additionally enhance the signal reception quality.
Maintenance / Cleaning
The DCF Receiver works maintenance-free. If the sensor becomes excessively soiled, it can be cleaned
with standard household cleaning products as long as they do not contain any aggressive or abrasive
ingredients.