Information for the installer – Control box
Connecting decentralised controls
The control system is designed for the connection of decentralised controls. The switching current of the
decentralised controls must not exceed 6 A. Each output has its own terminal for retraction and exten-
sion and is protected via a common 6.3 AT fine-wire fuse F2 in the control system.
Ä
ATTENTION!
–
When connecting decentralised control devices, do NOT fit a wire bridge
between the terminals L and Common. Fitting a wire bridge will destroy all
connected decentralised controls!
–
It is NOT permitted to operate floating controls and 230VAC motors at the
outputs of the control at the same time. If you need to operate motors and
decentralised controls, an isolating relay MC TR 1 PF (01054720) must be used
for each channel group that requires a floating output.