Information for the user – Fine adjustments detail 1/5
Setting runtime for temperature threshold 2
I
NOTE!
This function is only possible for assignment of
skylights with analogue temperature sensors TS Pro
XL or display box. If threshold 1 is set to
off
, this menu
is
not
visible.
In this menu, an additional motor runtime is set which is
enabled when temperature threshold 2 is exceeded. Buttons
and can be used to adjust the number of seconds that the
motor runs so that the skylight partly opens.
Programmable range:
off,
1 – 120 seconds
Press
to return to the temperature threshold 2 menu.
Press for the temperature reset delay menu.
Setting temperature reset delay
I
NOTE!
This function is only possible for assignment with
analogue temperature sensors TS Pro XL or display
box. If threshold 1 is set to
off
, this menu is
not
visible.
The reset delay delays sunshade retraction or skylight closure
after the temperature drops below the set threshold. A reset
delay can be set (in minutes) using the and buttons.
Programmable range: 1 – 60 minutes
Press
to return to the runtime for temperature threshold 2
menu.
Press for the temperature unit menu.
Setting temperature unit
I
NOTE!
This function is only possible for assignment with
analogue temperature sensors TS Pro XL or display
box. If threshold 1 is set to
off
, this menu is
not
visible.
In this menu, you have the option of displaying the tem-
perature unit in degrees Celsius (°C), kelvin (K) or Fahrenheit
(F). To set the temperature unit, press the appropriate symbol.
The symbol will then appear by the selected unit.
Press
to return to the temperature reset delay menu.
Press to go to the detail 1/5.