© Vestamatic GmbH
Subject to modifications!
- 16 -
Art.
-N
r.:
84
50
060
1
K
1•
V
est
amatic G
m
bH • Do
hr
w
eg
27 •
D
-41
066 M
önc
he
ngladb
ach •
www.v
est
amatic.
co
m
Information for the installer – Control box
Terminals
The two wind sensors are connected to the terminals Wind 1 and GND and Wind 2 and GND at the
control box. The polarity of the wind sensors is not important for connection.
Figure:
Connection samples for wind sensors
Ä
ATTENTION!
It is not permitted to have two different types of wind sensors connected at the
same time. Is no wind sensor connected, the terminals of the windsensor have to
be bridged by a wire bridge.
Assembly / Connection of lux sensors
Operation
The lux sensor is used to record natural light intensity and is adjusted to eye sensitivity. The measured
sun intensity is transformed into electrical analogue signals. These are evaluated by the control system,
which triggers the corresponding control commands.
Assembly of lux sensor LS 30
The lux sensor LS 30 can be installed on the aluminium mounting bracket article-no. 01100510, on the
plastic mounting bracket article-no. 01271020, or using the angled aluminium mounting bracket supplied.
Align so that the cable inlet is pointing downwards. Use clips, cable ties or similar fasteners to attach the
measuring cable securely to the mounting bracket so that the cable cannot be damaged by flapping and
fraying during high winds.