0046 Genlock to SDI Timing Adjustment
0046 Genlock to SDI Timing Adjustment
This command adjusts the relative position of the SDI output to that of the Com-
posite Genlock input. This command only applies to Genlock operation (refer to
command 0016h).
Horizontal Adjustment:
Horizontal Adjustment is in terms of 74.25MHz / 74.175MHz clock delays. The
Horizontal Adjustment is an 12-bit unsigned delay with adjustment range as follows:
• Valid Range for 1080i: 0 to 1920
• Valid Range for 720p: 0 to 1650
Vertical Adjustment:
Vertical Adjustment is 0 to 63 Lines, using an 6-bit value.
Switch Line Number:
This is a 6-bit value containing line number when the video switch is performed.