VEGAPULS 56K
35
Openings in a surge pipe for mixing of inhomogene-
ous products
Mounting and installation
slightly inhomogeneous
liquids
homogeneous
liquids
Pipe antenna with DN 50, DN 80, DN 100 and DN
150
DN 150
DN 80
DN 50
ø 150
ø 80
ø 50
DN 100
ø 100
diameter of the surge pipe must have a larger
nominal width, e.g. 100 mm, so that build-up
does not cause measuring errors. Surge pipe
diameters of DN 50 to DN 150 can be con-
nected.
Standpipe measurement in inhomoge-
neous products
Polarisation direction
For reasons of radar signal polarisation the
strongly inhomogeneous
liquids
inhomogene-
ous
liquids
If you want to measure inhomogeneous or
laminated products in a surge pipe, it must
have holes, long holes or slots. These open-
ings ensure that the liquid is mixed and corre-
sponds to the other vessel liquid.
The more inhomogeneous the measured prod-
uct, the closer the openings should be.