10
VEGAPULS 56K
2 Types and versions
VEGAPULS 56 sensors are a new developed
generation of very compact high temperature
radar sensors. For the first time it is now
possible to carry out a non-contact level
measurement under high temperatures and
pressures. They open the advantages of a
radar level measurement for applications
where the special advantages of radar were
formerly not applicable due to the extreme
process conditions.
VEGAPULS 56 radar sensors dominate the
two-wire technology perfectly. They are the
first radar sensors transmitting the supply
voltage and the output signal via one two-wire
line. An analogue 4 ... 20 mA-output signal is
available as output or measuring signal.
2.1 Type survey
Types and versions
VEGAPULS 56
DN 150
VEGAPULS 56
DN 80 pipe
antenna
VEGAPULS 56
DN 50 pipe
antenna
General features
• level measurement on process and products
under high temperatures and high pressures
• measuring range 0 … 20 m
• Ex-approved in Zone 1 and Zone 10 (IEC) or
Zone 0 and Zone 20 (ATEX) classification
EEx␣ ia␣ IIC␣ T6 or EEx d ia IIC T6
• integral measured value indication
• external measured value indication which
can be mounted up to 25␣ m separated in
Ex-area
Survey of features
Signal output
– 4 … 20 mA active (four-wire sensors)
– 4 … 20 mA passive (two-wire sensor)
Voltage supply
– two-wire technology (voltage supply and
signal output via one two-wire line)
– four-wire technology (voltage supply sepa-
rated from the signal line)
Process connection
– DN 50; ANSI 2“
– DN 80; ANSI 3“
– DN 100; ANSI 4“
– DN 150; ANSI 6“
– DN 200; ANSI 8“
– DN 250; ANSI 10“
Adjustment
– PC
– adjustment module in the sensor
– adjustment module in external indicating
instrument
– HART
®
-handheld
Antennas
– horn antenna with stainless steel horn and
ceramic tip
– standpipe antenna only with ceramic tip