52
VEGAPULS 56K
Set-up
sensor that e.g. at␣ 0 %-filling there are still 45
litres and at 100 %-filling 1200 litres in the
vessel. The sensor indication then indicates
with empty vessel (0 %) 45 litres and with full
vessel (100 %) 1200 litres.
As parameter you can choose
"dimensionless
(figures),
volume, mass, height and distance“
and an appropriate unit (e.g. l, hl) can then be
coordinated to the parameter. The sensor
indication shows then the figure in the
selected parameter and unit.
• Save the adjustments in the menu "
Scaling“
by confirming with "
OK“.
The adjustments are now transmitted to the
sensor.
Linearisation
When in your vessel there is another depend-
ence between product distance and the %-
value of the filling than a linear one, choose in
the menu window "
Conditioning“ the menu
point "
Linearisation“.
• Click to "
Linearisation“.
The menu window "
Linearisation“ opens.
Pre-adjusted is a linear dependence bet-ween
the percentage value of the filling. Beside the
two programmed linearisation curves "
Cylindri-
cal tank“ and "Spherical tank“ you can also
enter several "
user programmable curves“.
• Click to "
Scaling“.
In the menu "
Scaling“ you adjust the actual
0 %- and 100 %-values of the parameter as
well as its unit. This is the information for the