VEGAPULS 56K
63
with
medium
Min-
adjust.
at %
XXX.X
Max-
adjust.
at %
XXX.X
Signal
condit-
ioning
Scal-
ing
0 %
corre-
sponds
XXXX
100 %
corre-
sponds
XXXX
Deci-
mal-
point
888.8
Prop.
to
Mass
Unit
Kg
4. Conditioning
Under the menu point "
Conditioning“ you
choose the measuring distance at 0 % and at
100 %-filling. Finally you adjust the parameter
and the unit as well as the decimal point.
Enter in the menu window "
0 % correspond“
the figure of the 0 %-filling. In the example of
the adjustment with the PC and the adjustment
software VVO this would be 45 for 45 litres.
• Confirm with "
OK“.
With the "—>“-key you change to the 100␣ %-
menu. Enter the figure for your parameter
100.0%
at
m (d)
XX.XXX
(Max-adjustment)
OK
Set-up
Ad-
just-
ment
Pa-
ram-
eter
adjust-
ment
Sensor
m(d)
4.700
without
medium
Adjust-
ment
in
m(d)
0.0 %
at
m (d)
XX.XXX
(Min-adjustment)
OK
OK
+
OK
OK
%-filling (example: 5,850␣ m)
If you do not know the distance, you have to
measure.
The indication stops
flashing and the adjust-
ment will be saved.
Hence you have adjusted the min. value.
For level detection outside the operating
range, the operating range must be corrected
appropriately in the menu "
Sensor
optimisation/Meas. environment“.
Carry out the max. adjustment like the min.
adjustment with "
+“, "–“ or "OK“ (example:
0,300 m).
Adjustment with medium
Fill the vessel e.g. to 10 % and enter 10 % in
the menu "
Min-adjustment“ with the "+“ and "–
“-keys. Then fill the vessel e.g. to 80 % or 100
% and enter 80 % or 100 % in the menu "
Max-