VEGAPULS 56K
2
4
4 ... 20 mA
2
2
2
Types and versions
Measuring system with VEGAPULS 56K Ex, 56K Ex0 via a safety barrier in
Ex-area on active DCS
• Two-wire technology (loop powered), supply via the signal line from the DCS; output signal 4
… 20 mA (passive)
• Safety barrier transfers the not-intrinsically safe DCS-circuit into an intrinsically safe circuit, the
sensor can then be used in Ex-zone 1 (VEGAPULS 56K Ex) or in zone 0 (VEGAPULS 56K Ex0)
• Max. resistance of the signal line 15
Ω
per wire
• Optionally external indicating instrument with analogue and digital indication (can be mounted
up to 25 m separated from the sensor)
• Adjustment with PC, HART
®
-handheld or adjustment module MINICOM (can be plugged into
the sensor or in the external indicating instrument VEGADIS 50)
HART
®
-
handheld
Ex-area
Not Ex-area
Safety barrier
(see "3.3␣ Approvals“)
VEGA-
CONNECT 2
VEGADIS 50
Ex
passive
1)
DCS
EEx ia
1)
4␣ …␣ 20␣ mA passive means that
the sensor takes level dependent
a current in the range of
4␣ …␣ 20␣ mA. The sensor reacts
then electrically like a consumer
on the DCS.