I
NSTALLATION
: P
OWERING
U
P
2
0 2 . 9 6 7 3 . 0 0 0 1 A
22 - May- 0 1
21
Powering Up
Power-Up Procedure
Since Lamp On is the default state, the lamp will strike when the luminaire is powered
up for the first time. When AC power is applied, the luminaire will immediately begin
a calibration sequence that steps it through full pan and tilt movements. The internal
color, gobo, and beam mechanisms will also move through a full range of motion.
After calibration, the luminaire head will either stop at its "home" position (which
positions the pan axis at mid-rotation and the head parallel to the yoke with the lens
pointing away from the luminaire upper enclosure) or move to its current DMX-
defined position if DMX data is present. All internal mechanisms also move to their
"home" or DMX-defined positions.
Subsequently, depending on the luminaire’s setting for Lamp Power-Up State (refer to
“Menu System Functions” on page 60
), when power is applied, the arc lamp will
either
a)
"strike" or ignite - Lamp On (
default)
,
b)
await calibration and then strike -
Cal On, or
c)
await manual command to strike - Lamp Off.
CAUTION:
Before applying power, be sure the luminaire is hung or positioned so
that the head and yoke can move freely without restriction.
To power up:
1. At each luminaire, apply power by switching power switch to "
I
" (ON)
position. Luminaire will automatically step through following procedure:
a. If Lamp Power-Up State is set to Lamp On, lamp will strike (ignite).
b. Luminaire will cycle through calibration and stop at "home" position.
c. If Lamp Power-Up State is set to Cal On, lamp will strike (ignite) at end
of calibration sequence.