Utah-400 Components
4-24
Utah-400 Components
Crosspoint Control Module LED Indications
Internal Fail Alarm (Red)
Lit when the card is experiencing a problem with its internal power supplies.
Reset (Red)
Indicated when the card is in a stand-by mode.
Power Supply Fail (Red)
Indicates a problem with one of the UT-400’s power supplies.
Active (Green)
Indicates the current card is ‘active’ when lit.
MX Bus Active (Green)
Data is being received correctly.
Fan Fail (Red)
Indicates a problem with one if the four cooling fans.
Note: In redundant systems, all red LEDs flashing (at the same rate) on a given
crosspoint card indicates standby (or inactive) status.