144x144 Router
5-7
Control Subsystem Troubleshooting Table
Control Subsystem Troubleshooting Table
Use the following table to troubleshoot specific control subsystem problems. The numbers in
the left-hand column indicate specific references from the Control column in the
Main Trou-
bleshooting Table
.
TABLE 2-5.
Control Subsystem Troubleshooting Table
Problem
Check
1
No control of any level
•
Internal controller operating (see below)
•
External controller connected
•
Control panels connected (see below)
•
MX bus terminated (see below)
•
U-Net terminated (see below)
•
Completed controller software upgrade
2
No control of individual sig-
nal level or levels
•
MX bus cable connected (see below)
•
MX bus correctly terminated (see below)
•
Is non functional signal level address set correctly (see
•
below).
•
Control panel programmed correctly (see "Operations")
•
Output locked or protected on that level (see "Opera-
tions")
3
Control panel not functional
•
Panel address set to unique number
•
Completed panel software upgrade
4
Serial control port not func-
tional
•
Communications baud rate incorrect
•
Serial control Protocol incorrect
•
Serial control cable wired correctly
5
Ethernet port not functional
•
Ethernet option fitted
•
Connected to PC directly by null cable
•
Connected to network via gateway
6
Alarm active
•
Active CPU indicator extinguished (SC-4)
•
Heartbeat indicator extinguished (SC-4)
•
MX activity light does not flash (SC-4)
Summary of Contents for Utah-400
Page 1: ...The Utah 400 Digital Routing Switcher 144x144 Systems System Setup and Operation ...
Page 14: ...TOC 6 The Utah 400 ...
Page 18: ...F 4 List of Figures ...
Page 31: ...144x144 Router 1 13 System Configurations FIGURE 1 4 144x144 with Redundant Crosspoints ...
Page 32: ...Introduction 1 14 Introduction ...
Page 66: ...Configuration and Operation 3 10 Configuration and Operation ...
Page 94: ...Utah 400 Components 4 28 Utah 400 Components ...
Page 124: ...Troubleshooting 5 10 Troubleshooting ...