Utah-400 Components
4-20
Utah-400 Components
DS10-DS12 represent a 3-bit data rate indication
These LEDs change at about a 1 second rate, giving you status of all of the re-clockers in
about seven seconds.
If the onboard MPU cannot access the re-clocker chips to control them, DS10-DS17 will be set
in a ‘55’ pattern to indicate a communication problem.
Fiber Operation at 3 Gb/Sec.
The 121116-2 Input and 121117-2 Output cards that are revision B or later are capable of 3 Gb/
Sec. SMPTE-424 operation. They must be used in conjunction with the Gennum G02920 Dual
Optical Receiver (input) or the Gennum G02922 Dual Optical Transmitter (output) in order to
be SMPTE-424 compliant.
If the boards are used with the SP2R receiver or SP2T transmitter, they will work fully with
signals up to HD-SD1 SMPTE 292, but not with 3G-HD signals.
Rate
DS10
DS11
DS12
None
OFF
OFF
OFF
270 Mb/S
OFF
ON
OFF
360 Mb/S
OFF
ON
ON
540 Mb/S
ON
OFF
OFF
1.5 Gb/S
ON
OFF
ON
3.0 Gb/S
ON
ON
OFF