DS1067-035A
9
LBT8633
M Red
LED
tamper memory
Off
= no tamper
On
= tamper memory
See § 2.4.4
N Green
LED
System status
On
= system totally armed
Off
= system totally disarmed
Blinking
= system partially armed
See § 2.4.1
O
Arrow keys
Scroll the menu items; change the value of some parameters.
P
MENU
key
Access to the menu.
Q
ESC
key
Back to the upper level menu
R
OK
key
Confirms the access code or any other entered data; confirms the selected
menu item and goes to its submenu.
S
Cover
It protects numerical keys.
2.2
ELECTRONIC KEY READER 1067/334–1067/335 AND PROXIMITY READER 1067/434 – 1067/435
Description
Use or provided indications
1
2 3
(Green) LED for status of
associated zones
Off
= all zones associated to the LED are not active
On
= all zones associated to the LED are active
Blinking
= at least one zone associated to the LED is active
A
Yellow LED
summarising alarms and
signalling
Off
= no signalling for zones associated to electronic key reader
On
= alarm signalling stored for zones associated to electronic key reader
or tampering signalling or system failure signalling (the LED goes off at
next system arm, if the alarm has gone off in the meantime or until the
failure is repaired).
Blinking
= at least one open input is present among zones associated
electronic key reader.
If alarms or failures and open inputs are present at the same time, the
LED is on steady.
In general putting on this LED is for suggesting to control signalling details
on system keypad.
B
Keyhole or
Transponder
1067/334 – 1067/35 hole to insert electronic key.
1067/434 – 1067/435 detector for transponder key.
2.3
1058/035 REMOTE CONTROL
NOTE:
device utilizable with 1067 control panel and 1067/021 keypad software version 3.00 or higher and with an
1067/010 radio expansion.
Ref.
Description
Use or provided indications
A
Bi-colour LED
Red / Green
ON Red
= this LED goes on blinking when
pressing any key, followed by a beep if the
control unit has received the command.
ON Green
= pressing any key, this LED
indicates the low battery status.
Key 1
Arm
This key arms the zones associated.
Key 2
Programmable
depending on the
control unit
This key is set univocally either to OUTPUT
device arm/disarm function or to generate 4
different alarm types: Silent Panic, Audible
panic, Emergency, Fire alarm.
Key 3
Arm/disarm
Toggle
This key Arms/ Disarms with toggle function
the zones associated
Key 4
Disarm
This key disarms the zones associated