4.12 ADVANCED
PROGRAMMING
4.12.1 Remote management system code setting
To set the system code used for remote management with FastPro 1067/001 software, follow the instructions below:
1. Enter on the keypad the Installer code (default 000000) and press
OK
key.
2. Press
MENU
key.
3. Press
▼
key until “PROGRAMMING” appears on the display.
4. Press
OK
key to confirm.
5. Press
▼
key until “ADVANCED” appears.
6. Press
OK
key to confirm.
Press
▼
key until “ADVANCED” appears.
7. Press
OK
key to confirm. The system code appears. Enter the new code, with 8 digits.
8. Press
OK
key to confirm the code and then
ESC
key repeatedly to exit from the menu.
4.13 SYSTEM GENERAL PARAMETERS - TIMING
The system general parameters that can be configured are the following:
•
Burglar / Tamper / Panic alarm time
: it is the activation time of alarm outputs (for example the siren sound time) for
burglar, tamper and panic alarms. It is possible to select: 30, 60, 90, 180 seconds and 9 minutes
•
Pre-alarm time
: it is the activation time of pre-alarm outputs (for example siren sound time). It is possible to select:
30, 60, 90, 180 seconds and 9 minutes.
•
Emergency alarm time
: it is the activation time of outputs (for example siren sound time) for emergency alarms. It is
possible to select: 30, 60, 90, 180 seconds and 9 minutes.
•
Alarms count
: it is the number of alarm repetitions allowed to each excludible burglar input, also when new alarms
are present; “DISABLED” means that alarm warnings will be generated at each new event. The function is useful to
prevent the detector from sending out an excessive number of alarms during an arming cycle, so disturbing the
peace.
The values that can be selected are: DISABLED, 2, 4, 6 and 8.
Limit selected is the only one throughout the system and alarms count is performed for each excludible burglar input.
When the count involving an input has reached limit set, that input is automatically excluded; the event is recorded to
historic file (and relating keypads LED goes on).
The alarms count of each input is reset:
o
when all zones associated to it with function AND are disarmed
o
when at least one zone associated to it with function OR is disarmed
o
when time 24.00 is being passed.
•
Lack of power time:
it is time that must elapse without mains before the Lack of power event is generated. Times
that can be selected are: 1, 2 and 4 hours.
To change system general parameters follow the instructions below:
1. Enter on keypad the Installer code (default 000000) and press
OK
key.
2. Press
MENU
key.
3. Press
▼
key until “PARAMETERS” appears on the display.
4. Press
OK
key to confirm.
5. Press
▼
key until the parameter to be changed appears and confirm with
OK
key.
6. Change the value by using
▼
and
▲
keys. Press
OK
key to confirm the new value.
7. Change another parameter, by following the same procedure from point 4, or press
ESC
key repeatedly to exit from the menu.