DS1067-035A
30
LBT8633
4.7.4 Output
programming
To program an output follow the instructions below:
1. Enter on keypad the Installer code (default 000000) and press
OK
key.
2. Press
MENU
key.
3. Press
▼
key until “PROGRAMMING” appears on the display.
4. Press
OK
key to confirm.
5. Press
▼
key until “OUTPUTS” appears.
6. Press
OK
key to confirm. Select with the
▼
key if programming the control panel outputs
or those of any expansion configured.
7. Press
OK
key to confirm.
Select with
▼
key the desired output.
8. Press
OK
key to confirm.
9. Press
OK
key and after
▼
key until “OUTPUT TYPE” appears.
10. Press
OK
key to display the types of available outputs (N.L. – N.H. – Not used). Select
desired type with
▼
and
▲
keys and confirm it with
OK
key.
11. Press
▼
key until “ASSIGN” appears.
12. Press
OK
key to confirm.
13. Press
OK
key to select SYSTEM and with
▼
and
▲
keys select “DO NOT ASSIGN”, in
order not to associate the output to any zone, or “ASSIGN” to associate it to all the zones,
by confirming selection with
OK
key.
14. Otherwise it is possible to associate to the output the single zones by pressing
▼
key until
“ZONES” appears.
15. Press
OK
key to confirm.
Select desired zones and press
OK
key to confirm
16. Press repeatedly
ESC
key until “ASSIGN” - “ZONES” appears again.
17. Press
▼
key until “CUSTOMIZE” appears.
18. Press
OK
key
to display the configuration of available outputs. Select desired configuration
with
▼
and
▲
keys and confirm it with
OK
key.
19. Press
▼
key until “NAME” appears on the display.
20. Press
OK
key to confirm.
Give the output a descriptive name, by using the keypad (for further information see
paragraph 4.2
Alphanumeric characters input
).
21. Press
OK
key to confirm. “NAME” appears again.
22. Program the other control panel outputs by following the same procedure from point 7.
23. If the system has expansions, press
ESC
key until “CONTROL PANEL” appears again on
the display.
24. Press
▼
key to display “EXPANSIONS”.
Confirm by pressing
OK
key, select the desired expansion with
▼
and
▲
keys, confirm
selection by pressing
OK
key, then program all its outputs with the same procedure used
for control panel outputs programming.
25. Program all the expansions and at the end press
ESC
repeatedly to exit from the menu
NOTE:
commandable outputs maximum number is 10. The logical address of these outputs must be from 01 to 10.
UT00:INSTALLER
PROGRAMMING
PROGRAMMING
ZONES
PROGRAMMING
OUTPUTS
OUTPUTS
CONTROL PANEL
CONTROL PANEL
UC.U1: U01
UC.U1: U01
OUTPUT TYPE
UC.U1: U01
ASSIGN
ASSIGN
SYSTEM
ASSIGN
ZONES
ZN01:...
□□□□□□
UC.U1: U01
CUSTOMIZE
UC.U1: U01
NAME
NAME
U01:...
UC.U1: U01
NAME
OUTPUTS
CONTROL PANEL
OUTPUTS
EXPANSIONS