APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
990-333
E-21
Command
MONITOR
schedule_number
<crlf>
MONTYPE1
{ KA | V | KW }
<crlf>
UPPER1 {
limit_value
}
<crlf>
LOWER1 {
limit_value
}
<crlf>
ACTION1
{ none | STOP | INHIBIT | APC }
<crlf>
MONTYPE2
{ KA | V | KW }
<crlf>
UPPER2 {
limit_value
}
<crlf>
LOWER2 {
limit_value
}
<crlf>
ACTION2
{ none | STOP }
<crlf>
NOTE:
If your HF25 Control has a software version
lower
than, 1.29 you will
not
see the
parameters below.
P1LDLY1
{
delay_value
}<crlf>
P1LDLY2
{
delay_value
}<crlf>
P1UDLY1
{
delay_value
}<crlf>
P1UDLY2
{
delay
_
value
}<crlf>
P2LDLY1
{
delay_value
}<crlf>
P2LDLY2
{
delay_value
}<crlf>
P2UDLY1
{
delay_value
}<crlf>
P2UDLY2
{
delay
_
value
}<crlf>
<lf>
Control State
Any
Description
Reports the settings of the weld monitor of the currently loaded Control schedule. The
schedule_number
variable identifies which schedule is currently loaded, and may be any
value from 0 to 99. The possible value for all variables listed after their parameter name
correspond to the values listed under
MONITOR
in
Host Originated Commands
of this
manual.