APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
E-12
990-333
Command
SECURITY {OFF | SCHEDULE | SYSTEM | CALIBRATION}
<crlf><lf>
Control State
Any
Description
Allows control of the system security mode.
“OFF” sets all security status Control to “OFF.”
“SCHEDULE” sets the schedule lock to “ON.”
“SYSTEM” sets the system lock to “ON.”
“CALIBRATION” sets the calibration lock to “ON.”
Command
KEY {
key_code
}<crlf><lf>
Control State
Some key codes only function in certain states.
Description
Process the key_code as if it was pressed from the front panel.
The followings are the key_code:
KEY DEC
HEX KEY DEC
HEX
SQUEEZE 58
3A
5
53
35
UP 1
59
3B
6
54
36
WELD 1
60
3C
7
55
37
DOWN 1
61
3D
8
56
38
COOL 62
3E 9
57
39
UP 2
63
3F
PERIOD
46
2E
WELD 2
64
40
KA
4
04
DOWN 2
65
41
V
5
05
HOLD 66
42 kW 6
06
UP 30
1E RUN 15
0F
DOWN 31
1F MENU 23
17
0 48
30
ENERGY
10
0A
1 49
31
PEAK
3
03
2 50
32
3 51
33
SCHEDULE
8
08
4 52
34