APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
990-333
E-19
Command
SCHEDULE
schedule_number
<crlf>
ENG1
weld_energy
<crlf>
FEEDBACK1
{ KA | V | KW }
<crlf>
ENG2
weld_energy
<crlf>
FEEDBACK2
{ KA | V | KW }
<crlf>
SQUEEZE
squeeze_time
<crlf>
UP1
weld_time
<crlf>
WELD1
weld_time
<crlf>
DOWN1
weld_time
<crlf>
COOL
weld_time
<crlf>
UP2
weld_time
<crlf>
WELD2
weld_time
<crlf>
DOWN2
weld_time
<crlf>
HOLD
hold_time
<crlf>
VMULT
volt multiplier
<crlf>
RINDEX1
resistance_index
<crlf>
RINDEX2
resistance_index
<crlf>
EINDEX1
energy_index
<crlf>
EINDEX2
energy_index
<crlf>
<lf>
Control State
Any
Reports the settings of the currently loaded Control schedule parameters. The
schedule_number
variable identifies which schedule is currently loaded, and may be any
value from 0 to 99.
squeeze_time
and
hold_time
are the parameter that defines the time for the given period in 1
msec. Valid range is from 0 to 999.
weld_
time is equivalent to 0.01 for Increments from 0.1 to0.99 msec and increments of 0.1
msec for 1.0 to 9.9 msec and increments of 1.0 msec for 10.0 to 99.0 msec. (see table below)
HOST CONTROL
Increments Range Time
Range
Increments
0.01
0.1-0.99
0.1-0.99 ms
0.01
Description
0.1
1.00-9.90
1.0-9.9 ms
0.1 ms
1.0
10.00-99.0
10.0-99.0 ms
1 ms