APPENDIX E. COMMUNICATIONS
HF25D LINEAR DC RESISTANCE WELDING CONTROL
990-333
E-3
For RS-485 communication, do
not
exceed the capacity of each channel. The product of:
(total number welds per second on all welders on that channel)
times
(total number of bytes exchanged per weld)
times
(8 bits per byte)
must
in all cases remain
less
than the theoretical maximum capacity of the channel – the baud rate
selected on the unit. This capacity is not an issue on RS-232 channels.
A good guideline is that on a line free of electrical noise, the number calculated above must remain less
that 70% of the theoretical maximum capacity. Electrical noise on the communications lines will further
reduce this capacity. Shielded cables are recommended.
Several commands require the unit to be in
HOST
mode for the unit to accept them. Those commands
include the
REPORT
command and all
SET
commands. See the
MASTER CNTL
command in
Chapter 3
and the
REMOTE
command below for more information.