APPENDIX C: SYSTEM TIMING
HF25D DC RESISTANCE WELDING SYSTEM
990-333
C-3
Basic Weld Operation: System with Remote Firing Switch
NOTE:
The firing switch mode is selected under the Setup 1 menu.
Definitions
DELAY
Delay time from Remote Schedule Select Signal ON to the start of the weld sequence
(that is, start of
SQZ
).
DELAY
time is 23 ms.
SQZ
Squeeze time. Selectable range is 0 to 999 ms.
UP
Up slope time. Selectable range is 0.0 to 99.0 ms.
WELD
Weld time. Selectable range is 0.0 to 99.0 ms.
DOWN
Down slope time. Selectable range is 0.0 to 99.0 ms.
COOL
Cool time. Selectable range is 0.0 to 99.0 ms.
HOLD
Hold time. Selectable range is 0 to 999 ms.
.