Measuring period of the specified channel waveform, <source> take value as CHANnel1,
CHANnel2, CHANnel3 and CHANnel4. Ignore means the current channel.
Return format:
Query return 5.000e-003
,
unit is s.
:MEASure:PWIDth?
Command format:
:MEASure:PWIDth? [<source>]
Functional description:
Measuring positive pulse width of the specified channel waveform, <source> take value as
CHANnel1, CHANnel2, CHANnel3 and CHANnel4. Ignore means the current channel.
Return format:
Query return 5.000e-003
,
unit is s.
:MEASure:NWIDth?
Command format:
:MEASure:NWIDth? [<source>]
Functional description:
Measuring negative pulse width of the specified channel waveform, <source> take value as
CHANnel1, CHANnel2, CHANnel3 and CHANnel4. Ignore means the current channel.
Return format:
Query return 5.000e-003
,
unit is s.
:MEASure:FRR?
Command format:
:MEASure:FRR? <source1>,<source2>
Functional description:
Measuring time of the first rise edge between <source1> and <source2>, <source> take value as
CHANnel1, CHANnel2, CHANnel3 and CHANnel4.
Return format:
Query return 5.000e-003
,
unit is s.
:MEASure:FRF?
Command format:
:MEASure:FRF? <source1>,<source2>
Functional description:
Measuring time of the first fall edge between <source1> and <source2>, <source> take value as