10
GEORGIAN INSTALLATION
SECTION 4
=
GUTTERING ASSEMBLIES
NOTE: Fit all gu ering
mo f lo
to installing glazing bars
1
Gutter brackets
Measure & fit all gutter brackets supplied with the kit at maximum 750mm centres and
maximum 150mm from Unions and all stop ends. (See Fig. 1)
Position valley 90° internal angle if required. (See Fig. 1 general finished assembly)
NOTE: It is difficult to fit valley 90° Internal if the valley is already installed.
2a
Pre build up gutter assembly
Position the external 90° gutter angle
onto the eaves beam followed by any
union/outlet. Then measure between
the insertion lines (clearly marked on
the union/outlets) and cut the gutters to
length. Ensure to lubricate all rubber seals
prior to inserting the gutter into position
then snap the integral clips fitted to the
unions/outlets over the gutter.
2b
Insert gutter assembly and roll into position, critical to locate the back edge of each
section of gutter into the slot in the gutter bracket first.
NOTE: DO NOT push fit any union onto gutter as this can result in leaks.
2c
90° angle to overhang and then slide the
gutter assembly towards the host wall until
flush.
Fig. 1