Configuring with Turck Safety Configurator and Rockwell Studio 5000
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
56
The configuration change is done.
The software generates the new release circuits (OSSDs) if the following dialog box is closed with
"yes".
Again, the CIP Safety in- and output bits are automatically assigned.
HINWEIS
Release circuits (OSSDs) which are no longer used, have to be deleted.
New configuration (assignment of release circuits):
Inputs
FDX4/5
62. OSSD (new release circuit for the input)
FDI0/1
64. OSSD
FDI2/3
63. OSSD
Outputs
FDX6/7
4. OSSD
FDX4/5
3. OSSD (no longer necessary, will be deleted,
see
FSO0
2. OSSD
FSO1
1. OSSD