Configuring with Turck Safety Configurator and Rockwell Studio 5000
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
50
Standard Configuration
Outputs:
One OSSD (OSSD 1…OSSD 4) is created for each module output, which means to the safe outputs
FSO0 and FSO1 and the two SIL3-outputs FDX4/5 and FDX6/7. The outputs are automatically linked
to the first four CIP Safety input bits.
Inputs:
Additionally, one release circuit (63. OSSD and 64. OSSD) is created for each of the two SIL3-inputs
(FDI0/1 an FDI2/3). The inputs are also automatically assigned to the first two CIP Safety output bits.
Fig. 22: Release circuits (OSSDs) of the standard configuration