![Tritec SeaKing Profiling Sonar Product Manual Download Page 52](http://html1.mh-extra.com/html/tritec/seaking-profiling-sonar/seaking-profiling-sonar_product-manual_1168941052.webp)
Maintenance
SeaKing Profiling Sonar
0374-SOM-00002, Issue: 04
52
© Tritech International Ltd.
• A 5.5mm spanner, or nut spinner
• A small nose flush plier, or M2.5 spanner
Procedure
1. Carefully clean all parts and check for damage.
2. Inspect o-ring seals and replace if necessary.
3. Screw in the four guide posts onto the connector endcap
4. Fit the COM PCB and a set of four stand off posts
5. Refit each PCB and set of stand off posts
6. On the top most PCB, locate the two hexagonal pictures on the PCB
7. Using the 5.5mm spanner secure the retaining nuts at these locations
8. Using the short nose flush pliers, fit the bullet post at the remaining points
9. Carefully insert the electronics block back into the Body tube, ensuring that
the dowel pin on the connector endcap lines up with the recess point on
the Body tube
10.Fit the connector endcap locking ring
11.Using the M3 Allen key, fit the MAIN and AUX (if applicable) waterblocks.
Each of the waterblock screws should be tightened, in turn, by a quarter
turn until the waterblock is flush and level to the connector endcap
12.Using the M3 Allen Key, fit the Pressurised blanking cap (if applicable)
either directly onto the AUX port, or on the AUX waterblock if it not to be
used.
13.Visually inspect the unit to ensure that all surfaces have mated correctly