Operation
SeaKing Profiling Sonar
0374-SOM-00002, Issue: 04
34
© Tritech International Ltd.
Roll Setup
In this dialog, there are several settings to be configured:
Centre of Rotation
X
, 'Y'
Sets the X,Y co-ordinate position offset
which is relative to the Profiler display
datum (= origin 0,0).
Rotation Offset
R
A Roll Sensor alignment offset to correct
for any slew that may result when the Roll
Sensor is mounted off-centre.
Show Position Indicator
Toggles display of the
Centre
of
Rotation
position indicator ( O ) on the
Profiler display.
Overlay
This will display an overlay on the Profiler screen which can be used to mark/
highlight a particular area or object in the area. The Overlay can also be used
as a Gating Zone for the Gate Alarm function.
ID
Up to 4 overlays are selectable (IDs = 1,2,3 & 4).
Style
Is the desired shape; Circle (or ellipse), Rectangle
and Triangle are the available options.
Size
Width & Height of the Overlay.
Position
X & Y Position of the Overlay on the Profiler screen.