![Tritec SeaKing Profiling Sonar Product Manual Download Page 17](http://html1.mh-extra.com/html/tritec/seaking-profiling-sonar/seaking-profiling-sonar_product-manual_1168941017.webp)
Operation
SeaKing Profiling Sonar
0374-SOM-00002, Issue: 04
17
© Tritech International Ltd.
4.2.2. Profiler Settings
The Profiler head controls are displayed on the Sonar Settings bar. When a
RAT is used or screen cursor is moved over the Sonar Settings bar, a pop-
up control panel will appear which will display the remaining controls. These
mimic the positions of the rotary controls (C1 to C5) and function buttons (F1
to F7) on the RAT. Adjustments may be made using the RAT or the on screen
controls using the pointer device.
Note
F1, F2 are not applicable in single window applications, F7 and C2
are not used.
Sonar Gain (C1)
This sets the sonar receive gain as
required – typically this is around 25-40%
but is varied according to water and target
conditions and user preference.
Range (C3)
This sets the maximum range the sonar
will scan. Long ranges are scanned more
slowly than short ranges due to the limit
imposed by the velocity of sound in water.
Sector Scan Direction (C4)
This is used to set the centre of the
scanned sector and is particularly useful
when using a narrow sector width to
concentrate on a feature of the seabed.
A well positioned and narrow sector will
allow faster scan updates than a wide
sector.
Sector Scan Width (C5)
This sets the width of the scanned sector.
Typically this will be adjusted according to
the required seabed coverage.
CYC (F1) - Cycle Window
This can be used when one of the display
windows is maximised using the Expand
(F2) button and will cycle between the
Sonar display windows. Also use the F1