54
5.4 _OPTIMIZATION OPTIONS
The Altitude
16
’s optimization of the system can be switched on/off via the Main interface.
To switch on/off the optimization options, click on the “OPT. Trinnov Optimizer” menu item of the lateral
menu. The following Optimization options are available in this page:
• To activate/deactivate all of the Optimizer processing:
• The Trinnov Optimizer switch
• To activate/deactivate specific parts of the processing:
• The Acoustic correction switch
• The Level alignment switch
• The Delay alignment switch
Figure 44: Optimizer & Remapping page
• Trinnov Optimizer ON/OFF: switch on/off the automatic correction of the in-room response: the acoustic
correction, the automatic delay and level alignment, as well as the remapping options. When the Optimizer is off,
only the manual settings related to the audio processor are applied:
• Routing, as defined in Speaker Configuration Table in the 3D View page of the Main interface;
• The Active Xovers frequencies and filters;
• Levels, as defined in the Processor pages of the Advanced interface;
• Graphic EQs, as defined in the Processor pages of the Advanced interface;
• Bass Management, as defined in the Fine Tuning page of the Main interface.
• Acoustic Correction ON/OFF: when turned off, both the automatic equalization (defined by the target curve)
and the FIR EQs (defined in the Processor/Outputs page of the Advanced interface) are bypassed;
• Level Alignment ON/OFF: disable the automatic alignment of speaker levels, meaning that no automatic gain
changes will be applied to the outputs;
• Delay Alignment ON/OFF: disable the automatic alignment of speaker distances, meaning that no automatic