3.15
TRICOR Systems Inc.
3.5.8 Set Clock/Calendar (Cont'd)
Press the
Select
button to move to the next group of digits. It is suggested that
the year be set first, then the month and finally the day. The system is
automatically calculating valid dates and would not allow a date of 02/29/07,
where it would permit 02/29/08.
To accept the newly entered value, press and hold the
Select
button for 5
seconds. A message indicating the new date and time will be displayed
Settings Stored
The display will return to the previous menu showing the time and date that was
stored. Press the
Cancel
button to return to the Top Menu Selection.
If you decide not to change the time and date, press the
Cancel
button to return
without making the change. The date and time will have been changed if you
see the Settings Stored message.
In both cases the Top Menu Selection display will show again. To return to the
ready to test screen press the
Cancel
button.
3.5.9 Run Time
The run time is an option that must be purchased when ordering the Model 225.
If you do not have this option, selecting this menu group will cause a warning
message indicating that the feature is not available. The run time adjusts how
long the temperature profile is measured to find the inflection point. Some
products can get by with shorter run times, allowing more measurements to be
made. Other product may need extended run times because of higher initial
temperatures. The run time can be adjusted from 3:00 to 9:30 in 30 second
increments as well as 9:55. Standard test time is 5:00.
To change the Run Time, press the
Select
button from the ready to test screen.
Use the scroll buttons to choose the Run Time group.
Top Menu Selection
7 - Run Time