TAC-7X
MANUAL
Step 9.
Continue inserting the conductor; as the conductor strands
bottom out in the contact, the contact will be depressed
and,in turn, activate the trigger.
Step 10. When the trigger is fully activated, the crimp cycle is initiated.
When the crimp cycle is complete, the funnel will open.
Smoothly pull the conductor out immediately after the funnel
opens.
NOTE
Do not attempt to remove the conductor until the funnel
opens. A built in safety feature precludes the transfer
mechanism from returning to the vertical position until the
crimped contact is removed from the transfer tip.
Step 11. Visually inspect the crimp, as required. (See Figure 3-3).
Step 12. Repeat Steps 7 through 12 until all crimps are made. (Select the
proper "G" dimension setting if wire gauges change).
Step 13. Open the sleeve valve.
Step 14. Set the feeder-bowl power on-off switch to off.
Summary of Contents for TAC-7AE
Page 6: ...Figure 1 1 TAC 7X Front View ...
Page 8: ... Figure 1 2 Wire Insertion Through Funnel ...
Page 12: ...Figure2 1 Pneumatic Hook Up ...
Page 14: ... Fiqure 2 4 Track Drop Tube Escapement ESCAPEMENT SYSTEM _ _ _ BR ASSEMBL I TRA ...
Page 18: ... ARBOR COVER PLA TE REMOVED Figure 3 1 Crimp Cylinder Arbor Open ...
Page 20: ... ARBOR COVER PLAT E REMOVED Figure 3 2 Crimp Cylinder Arbor Closed ...
Page 23: ... Crimp Inspection Points Improper Crimps ...
Page 33: ...Figure 6 1 TAC 7X Components ...
Page 34: ...Figure 6 2 Control Box Components Figure 6 2 TAC 7X Components Right View ...
Page 37: ...Figure 6 3 Contact Track Feed Air Adjustments ...
Page 42: ... Figure 6 4 Indenter Plate Removal ...
Page 43: ...HOSE CLAMP CAREFULL Y REMOVE Figure 6 5 Indenter Replacement ...
Page 47: ...Figure 6 6 Indenter Adjustment ...
Page 52: ...TAC 7X Pneumatic Diagram ...