I
NTRODUCTION
Page 8
CineMonitor
HD
3DView RF
Installation
The CineMonitorHD must be securely mounted on the camera or on its location of use. Several
mounting points with
¼
-20” nut are present on this equipment for a secured professional use.
Do not use the monitor with loose fixation or damaged brackets for your own safety and that of
others working with you.
Transvideo manufactures high quality brackets and accessories for the comfort of use and security
for the equipment and user. Please contact Transvideo S.A. or its local representative in case of need
or visit http://www.hd4dp.com.
Power requirements
Only DC Voltage powers this product.
AC voltage can be used with an appropriate AC/DC converter
Recommended AC power adaptor for CinemonitorHD 3DView RF is the Transvideo AL63.
The input power voltage range is extremely wide from 10 to 36 V DC (except specified differently).
Power instructions
The power consumption slightly varies with the input voltage, the operating temperature and the
equipment configuration. The internal power supply is protected against reverse polarity. Over
voltage may cause severe damages to the equipment and/or to other equipment connected to it.
This product must be used in a properly grounded electrical environment. Ground defects can create
severe problems to the equipment and/or picture quality and may even cause danger for the user.
Turning power On/Off
The ON/OFF Switch is on the back side of the monitor.
The product needs a certain time to reach its nominal brightness.
This time can vary with the temperature.
In OFF position, the power consumption is null.
Galvanic insulation
For safety of use the CineMonitorHD family feature a galvanic insulation of the DC input. Do not
connect the power ground to the chassis of the monitor or to the metallic body of the power
connector in order to keep the galvanic insulation. The galvanic insulation is rated at 1000VDC. The
chassis of the monitor is connected to the video ground.
Anton-Bauer batteries / FuelReader
™
TransvideoLabs engineer’s integrated communication between the fuel computer of Logic Series
Digital batteries from Anton-Bauer and CineMonitorHD 3DView RF. The FuelReader™ gives to the
user a view of the remaining available percentage of the battery and the time to run.
WARNING RISK OF FIRE:
It is always recommended to remove the power source from the monitor when you do not use it
and/or when you travel. Especially if you place the monitor in a closed environment (bag, box, …).