Basic monitor information is indicated during the startup on the display:
SOFT
main board software version (microcontroller #1)
FIRMWARE
main board firmware version
HARDAWARE
main board hardware version
LOGO
graphical user interface version
LOAD MATRIX
colorimetry version
This information is useful to write down if trouble-shooting becomes necessary.
The complete list of software and firmware versions of all electronic boards may be found in MENU /
HELP / MONITOR INFO.
Updating your CineMonitorHD 3DView RF
All software and firmware updates are possible by the sole use of a USB key.
The following procedure sets how to proceed to update your monitor.
For CineMonitorHD 3DView RF with Software 12.xx only.
Step 1
Get the last software update package for your CineMonitorHD 3DView RF.
An update package is a .zip file that contains softwares and firmwares that are compatible each
other. It can be downloaded on our website for registered users by visiting
www.transvideo.eu/support
. You can also ask it directly to your local Transvideo representative.
Step 2
Uncompress the .zip using your archive utility software. Then paste
all
the files
at the root
of the
USB key.
Step 3
Plug in the USB key in the monitor by using the mini USB adapter (included with your product) and
turn on the monitor.
Step 4
Go to MENU / HELP and select UPDATE
Step 5
The update starts. Do not turn off the monitor neither remove the USB key until the update ends.
Follow the instructions on the screen.
Step 6
Wait for 2 green leds and restart the monitor.
Step 7
Go to MENU / HELP / MONITOR INFO and verify that the software and firmware versions match with
the update package.