[22] Protection functions [1/3]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Constant
Reference
H
0601
Stall prevention level
10~164%, 165:Deactivated
1/1
150 150 150
Enabled
●
/
●
●
6. 26. 1
H
0602
Inverter trip record retention selection
0:Clear when power is turned off
1:Retain even after power is turned off
1/1
0 0 0
Enabled
●
/
●
●
6. 26. 3
H
0603 Emergency
stop
0:Coast stop
1:Deceleration stop
2:Emergency DC braking
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 4
H
0604
Emergency DC braking control time
0.0~20.0 sec.
0.1/0.1
1.0 1.0 1.0
Enabled
●
/
●
●
6. 26. 4
H
0605
Output phase failure detection mode
selection
0:Deselect
1:At starting (only one time after power is
turned on)
2:At starting (each time power is turned on)
3:During operation
4:At st during operation
5:Output cut-off detection enabled
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 5
H
0606
OL reduction starting frequency
0.0~60.0Hz
0.1/0.01
6.0 6.0 6.0
Enabled
●
/
●
●
5.
14
H
0608
Input phase failure detection mode
selection
0:Disabled
1:Enabled
1/1
1 1 1
Disabled
●
/
●
●
6. 26. 7
H
0609
Low current detection hysteresis width
1~20%
1/1
10 10 10
Enabled
●
/
●
●
6. 26. 8
H
0610
Low current trip selection
0:No trip
1:Trip
1/1 0 0 0
Enabled
●
/
●
●
6. 26. 8
H
0611
Low current detection current
0~100%
1/1
0 0 0
Enabled
●
/
●
●
6. 26. 8
H
0612
Low current detection time
0~255 sec.
1/1
0 0 0
Enabled
●
/
●
●
6. 26. 8
H
0613
Selection of short circuit detection at
starting
0:Each time (standard pulse)
1:Only one time after power is turned on
2:Each time (short pulse)
3.Only one time after power is turn on (short
pulse)
4:Each time (Extremely shot-time pulse)
5.Only one time after power is turn on
(Extremely shot-time pulse)
1/1
0 0 0
Disabled
●
/
●
●
6. 26. 9
H
0615
Overtorque trip selection
0:No trip
1:Trip
1/1 0 0 0
Enabled
●
/
●
●
6. 26. 10
H
0616
Overtorque detection level during power
running
0~250% 1/0.01
150 150 150
Enabled
●
/
●
●
6. 26. 10
H
0617
Overtorque detection level during
regenerative braking
0~250% 1/0.01
150 150 150
Enabled
●
/
●
●
6. 26. 10
H
0618
Overtorque detection time
0.00~10.00 sec.
0.01/0.01
0.50
0.50
0.50
Enabled
●
/
●
●
6. 26. 10
H
0619 Overtorque
detection
hysteresis
0~100%
1/0.01 10 10 10
Enabled
●
/
●
●
6. 26. 10
H
0620
Cooling fan control selection
0:Auto
1:Always ON
1/1 0 0 0
Enabled
●
/
●
●
6. 26. 11
H
0621
Cumulative operation time alarm setting
0.1~999.9 (x100h)
0.1/0.1
610.0
610.0
610.0 Enabled
●
/
●
●
6. 26. 12
H
0622
Abnormal speed detection time
0.01~100.0 sec.
0.01/0.01
0.01
0.01
0.01
Enabled
-/
●
-
6. 26. 13