K-1
1
E6581531
11
[11] Preset speed operation frequency (8~15) [2/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
H
0290 Preset
speed operation frequency 11
NN
~
WN
Hz
0.1/0.01
0.0
0.0
0.0
Enabled
●
/
●
●
5. 12
H
0291 Preset
speed operation frequency 12
NN
~
WN
Hz
0.1/0.01
0.0
0.0
0.0
Enabled
●
/
●
●
5. 12
H
0292 Preset
speed operation frequency 13
NN
~
WN
Hz
0.1/0.01
0.0
0.0
0.0
Enabled
●
/
●
●
5. 12
H
0293 Preset
speed operation frequency 14
NN
~
WN
Hz
0.1/0.01
0.0
0.0
0.0
Enabled
●
/
●
●
5. 12
H
0294
Preset speed operation frequency 15
(Forced operation frequency)
NN
~
WN
Hz
0.1/0.01
0.0
0.0
0.0
Enabled
●
/
●
●
5. 12
H
0295 Bumpless
operation
selection
1:Disabled
2:Enabled
1/1 0 0 0
Enabled
●
/
●
●
6. 14
[12] Tripless intensification setup [1/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
EH
0300
PWM carrier frequency
2.5~6.0kHz (2.5~4.9kHz) *2
0.1/0.1
*2
*2
*2
Enabled
●
/
●
●
5. 17
WXU
0301
Auto-restart control selection
0:Disabled
1:At auto-restart
2:When turning ST operation standby signal on
or off
3:1+2, 4:Starting
1/1
0
0
0
Disabled
●
/
●
●
5. 18. 1
WXE
0302
Regenerative power ride-through control
0:Disabled
1:Power ride-through
2:Deceleration stop during power failure
1/1
0
0
0
Disabled
●
/
●
●
5. 18. 2
H
0303
Retry selection
0:Deselect, 1-10 times
1/1
0 0 0
Enabled
●
/
●
●
6. 15. 1
RD
0304
Dynamic braking selection
0:Disabled
1:Enabled (braking resistance overload detect)
2:Enabled (braking resistance overload not
detect)
1/1
0
0
0
Disabled
●
/
●
●
5. 19
H
0305
Overvoltage limit operation
0:Enabled
1:Disabled
2:Enabled (quick deceleration)
3:Enabled (dynamic quick deceleration)
1/1
2 2 2
Disabled
●
/
●
●
6. 15. 2
This parameter moves to a fundamental parameter.
*1: For 37kW and above,the carrier frequency is between 2.5 and 4.9kHz in inclusive.
*2: Default values vary depending on the capacity.
⇒
See the table of K-47.