K-12
E6581531
11
[12] Tripless intensification setup [2/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
H
0307
Base frequency voltage selection
(correction of supply voltage)
0:Without voltage compensation (limitless
output voltage)
1:With voltage compensation (limitless output
voltage)
2:Without voltage compensation (limited output
voltage)
3:With voltage compensation (limited output
voltage)
1/1
0 0 0
Disabled
*3
●
6. 15. 3
RDT
0308
Dynamic braking resistance
0.5~1000
Ω
0.1/0.1
*1
*1
*1
Disabled
●
/
●
●
5. 19
RDER
0309
Allowable continuous braking resistance 0.01~600.0kW
0.01/0.01
*1
*1
*1
Disabled
●
/
●
●
5. 19
H
0310
Non-stop control time/deceleration time
during power failure
0.1~320.0 sec.
0.1/0.1
2.0
2.0
2.0
Enabled
*2/
Disabled
●
/
●
●
5. 18. 2
H
0311
Reverse-run prohibition selection
0:Permit all
1:Prohibit reverse run
2:Prohibit forward run
1/1
0 0 0
Disabled
●
/
●
●
6. 15. 4
H
0312 Random mode
0:Disabled, 1:Enabled
1/1
0 0 0
Disabled
●
/
●
●
5.
17
H
0313
Output voltage waveform selection *4
0:PWM carrier frequency control 1
1:PWM carrier frequency control 2
1/1
0 0 0
Disabled
●
/
●
●
6. 15. 5
H
0316
Carrier frequency control mode selection
0:Not decrease carrier frequency automatically
1:Decrease carrier frequency automatically
2:Not decrease carrier frequency automatically,
600/690V class supported
3:Decrease carrier frequency automatically,
600/690V class supported
4:Not decrease carrier frequency automatically,
with sinusoidal filter
5:Decrease carrier frequency automatically,
with sinusoidal filter
1/1
3 3 3
Disabled
●
/
●
●
5.
17
H
0319
Regenerative over-excitation upper limit 100~160% 1/1
140
140
140
Disabled
●
/
●
●
6. 15. 2
This parameter moves to a fundamental parameter.
*1: Default values vary depending on the capacity.
⇒
See the table of K-47.
*2: Although the setting can be written into memory if
WXE
is set to
(power ride-through control), it cannot be written if
WXE
is set to
(deceleration stop during a power failure).
*3: Parameter is changeable, but fixed to "with voltage compensation" internally. When
H
is set to 0 or 1, fixed at 1 internally. When
H
is set to 2 or 3, fixed at 3 internally.
*4:
H
is available for VFAS1-6110KPC and above.