E6581531
L-3
12
3)Standard specifications (
Power supply is based on 690V
)
Item Specification
Voltage class
690V class
Applicable motor (kW)
3.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Type
VFPS1-
Form
6030PL 6055PL 6075PL
6110PL
6150PL
6185PL
6220PL
6300PL
6370PL
6450PL
6550PL 6750PL 6900PL
Output capacity (kVA)
[Note 1]
5.4 9.0 12 17 23 29 35 42 57 71 82 102 125
Output current
(A)
[Note 2]
4.5 7.5 10 13.5
18.5 24 29 35 47 59 68 85 104
Output voltage
Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Ra
ting
Overload current
rating
120%-1 minute, 135%-2 sec.
Dynamic braking
circuit
Built-in dynamic braking drive circuit
Ele
ctr
ic
al
br
ak
in
g
Dynamic braking
resistor
An external braking resistor
⇒
Rating: Refer to 5.19.
Voltage-frequency
Three-phase 500~690V-50/60Hz [Note 3]
Pow
er
su
pp
ly
Allowable
fluctuation
V 10% - 15% [Note 4] Frequency ±5%
Protective method
IP20
Cooling method
Forced air-cooled
Cooling fan noise (dBA)
64
Color
RAL7016
EMC filter
Built-in
Reactor
Built-in
Item Specification
Voltage class
690V class
Applicable motor (kW)
110 132 160 200 250 315 400 500 630
Type
VFPS1-
Form
6110KPC 6132KPC 6160KPC 6200KPC 6250KPC 6315KPC 6400KPC 6500KPC 6630KPC
Output capacity (kVA)
[Note 1]
150 180 215 263 347 424 502 649 806
Output current
(A)
[Note 2]
125 150 180 220 290 355 420 543 675
Output voltage
Three-phase 500V~690V (The maximum output voltage is equal to the input supply voltage.)
Ra
ting
Overload current
rating
120%-1 minute, 135%-2 sec.
Dynamic braking
circuit
Built-in dynamic braking drive circuit
External dynamic braking circuit(option)
Ele
ctr
ic
al
br
ak
in
g
Dynamic braking
resistor
An external braking resistor
⇒
Rating: Refer to 5.19.
Voltage-frequency
Three-phase 500~690V-50/60Hz [Note 3]
Pow
er
su
pp
ly
Allowable
fluctuation
V 10% - 15% [Note 4] Frequency ±5%
Protective method
IP00 [Note 5]
Cooling method
Forced air-cooled
Cooling fan noise (dBA)
73 76
78
Color
RAL7016
EMC filter
Built-in
Reactor
[Note 6] External AC reactor (option)
Note 1: Capacity is calculated at 690V for the 690V class.
Note 2: Rated output current when the PWM carrier frequency (parameter
EH
) is 2.5kHz.
⇒
Refer to 1.4.4 ”Current reduction curve” for details.
Note 3: An external power supply backup available (option) (Type: CPS002Z)
Note 4: ±10% when the inverter is used continuously (load of 100%).
Note 5: Inverters do not have wiring port covers. They have large openings, but there is no space to bend the
external cables inside the unit.
Note 6: AC reactor (option): Mandatory for VFPS1-6110KPC and above.