K-1
E6581531
11
11. Table of parameters
1. Basic parameter [1/4]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Default setting
Title
Communication
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
V[R
=
500V
-50Hz
V[R
=
575V
-60Hz
V[R
=
690V
-50Hz
Write
during
running
Vector
control
V/f
Reference
CWJ
- History
function
1/1 - - - -
●
/
●
●
5.
1
CW
0000 Automatic
acceleration/deceleration
0:Disabled
1:Automatic setting
2:Automatic setting (during acceleration only)
1/1
0 0 0
Disabled
●
/
●
●
5.
2
CW
0001 Automatic
torque
boost
0:Disabled
1:Automatic torque boost + auto-tuning 1
2:Sensorless vector c auto-tuning 1
1/1
0 0 0
Disabled
●
/
●
●
5.
3
CW
0040
Automatic function setting
0:Disabled
1:Frequency setting by means of voltage
2:Frequency setting by means of current
3:Voltage/current switching from external terminal
4:Frequency setting on operation panel and
operation by means of terminals
5:Frequency setting and operation on operation
panel
6:Coast stop
1/1
0 0 0
Disabled
●
/
●
●
5.
4
EOQF
0003 Command
mode
selection
0:Terminal input enabled
1:Operation panel input enabled (including
LED/LCD option input)
2:2-wire RS485 communication input
3:4-wireRS485 communication input
4:Communication option input
1/1
0 0 0
Disabled
●
/
●
●
5.
5
HOQF
0004
Frequency setting mode selection 1
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Operation panel input enabled (including
LED/LCD option input)
5:2-wire RS485 communication input
6:4-wire RS485 communication input
7:Communication option input
8:Optional AI1 (differential current input)
9:Optional AI2 (voltage/current input)
10:UP/DOWN frequency
11:Optional RP pulse input
12:Optional high-speed pulse input
13:- *1
1/1
2 2 2
Disabled
●
/
●
●
5.
5
*1: Unsupported option