E6581531
F-70
6
Trace data communication number
Communication
No.
Function
Minimum setting
/readout unit
Setting/readout range
Default setting
E000
Trace data 1~4 pointer
1/1
~
E100
Data 1 of trace data 1
1/1
~
HHHH
Data 2~99 of trace data 1
1/1
~
HHHH
E199
Data 100 of trace data 1
1/1
~
HHHH
E200
Data 1 of trace data 2
1/1
~
HHHH
Data 2~99 of trace data 2
1/1
~
HHHH
E299
Data 100 of trace data 2
1/1
~
HHHH
E300
Data 1 of trace data 3
1/1
~
HHHH
Data 2~99 of trace data 3
1/1
~
HHHH
E399
Data 100 of trace data 3
1/1
~
HHHH
E400
Data 1 of trace data 4
1/1
~
HHHH
Data 2~99 of trace data 4
1/1
~
HHHH
E499
Data 100 of trace data 4
1/1
~
HHHH
Ex.) When operation frequency data is acquired through a communication device
Data acquired (
H
) h=8000
⇒
8000×0.01Hz=80.0Hz
Relationship between pointer and data
The table below shows the relationship between pointer (E000 set value) and trace data (1 to 4).
Pointer (E000 set value)
~
Trace data 1
(
E100
~
E199
)
E100 E101 E102 ~ E198 E199
Trace data 2
(
E200
~
E299
)
E200 E201 E202 ~ E298 E299
Trace data 3
(
E300
~
E399
)
E300 E301 E302 ~ E398 E399
Trace data 4
(
E400
~
E499
)
E400 E401 E402 ~ E498 E499
<Example of setting> If E000 is set to
:
(Earliest data)
(Latest data)
Trace data 1
E102
~
E199, E100, E101
Trace data 2
E202
~
E299, E200, E201
Trace data 3
E302
~
E399, E300, E301
Trace data 4
E402
~
E499, E400, E401
Note 1: Use the parameters
H
through
H
to specify the types of trace data (1 to 4).
Note 2: Communication numbers E000 is automatically incremented by the inverter when data is traced
continuously.
* In ordinary cases, these parameters do not need to be rewritten.