J-
20
[33] Communication function(1/2)
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0800
Communication rate (common serial) 0: 1200, 1: 2400, 2:4800, 3: 9600
−
3
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0801
Parity (common serial/RS485) 0: No parity, 1: Even parity, 2: Odd parity
−
1
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0802
Inverter number(common)(*1) 0
〜
255
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0803
Communication time-out
(common serial/RS485)
0: OFF, 1
〜
100 [s]
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0804
Communication time-out action
(common serial /RS485)
0
〜
8
−
8
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0805
Communication waiting time
(common serial)
0.00: Normal, 0.01
〜
2.00 [s]
0.01/0.01
0.00
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0806
Inter-drive communication
(common serial)
0: Normal, 1: Frequency reference, 2: Output frequency,
3: Torque reference, 4: Output torque
−
0
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0810
Frequency point selection
0: Invalid, 1: Common serial, 2: RS485,
3: Communication add-on cassette option
−
0
Enabled
●
/
●
−
−
●
6.30
0811
Point #1 setting
0
〜
100 [%]
1/0.01
0
Enabled
●
/
●
−
−
●
6.30
0812
Point #1 frequency
0.0
〜
[Hz]
0.01/0.01
0.0
Enabled
●
/
●
−
−
●
6.30
0813
Point #2 setting
0
〜
100 [%]
1/0.01
100
Enabled
●
/
●
−
−
●
6.30
0814
Point #2 frequency
0.0
〜
[Hz]
0.01/0.01
80.0
Enabled
●
/
●
−
−
●
6.30
0820
Communication rate (RS485) 0: 1200, 1: 2400, 2: 4800, 3: 9600, 4: 19200, 5: 38400
−
3
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0821
RS485 wiring system
0: 2-line system, 1: 4-line system
−
1
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0825
RS485 communication waiting time 0.00: Normal, 0.01
〜
2.00 [s]
0.01/0.01
0.00
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0826
Inter-drive communication (RS-
485)
0: Normal, 1: Frequency reference, 2: Output frequency,
3: Torque reference, 4: Output torque
−
0
Enabled
●
/
●
●
/
●
−
/
●
●
6.30
0830
Data type
0, 1
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0831
Input reference setting #1
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0832
Input reference setting #2
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0833
Input reference setting #3
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0834
Input reference setting #4
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0835
Input reference setting #5
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0836
Input reference setting #6
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0841
Monitor output setting #1
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0842
Monitor output setting #2
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0843
Monitor output setting #3
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0844
Monitor output setting #4
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0845
Monitor output setting #5
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0846
Monitor output setting #6
0
〜
16
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0850
Mode at communication error 0
〜
4
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0851
Communication error detection time 0
〜
1000
1/1
200
Enabled
●
/
●
●
/
●
−
/
●
●
※
0860
Receiving address
0
〜
1023
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
0861
Transmitting address
0
〜
1023
1/1
0
Enabled
●
/
●
●
/
●
−
/
●
●
※
(*1): To be only monitoring available when using S20 option.
(*2): Parameters
,
,
,
, and
can be reflected at resetting (power OFF
→
ON).
※
(Reference section): Refer to the inverter's individual manual.
Sensorless vector/vector with sensor (
●
valid,
−
:invalid)