[16] Functions for lift (2/2)
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0340
Heavy load torque during fixed speed in reverse direction
0
〜
250 [%]
1
100
Enabled
●
/
●
−
−
●
※
0341
Automatic light-load high-speed operation frequency
30.0
〜
[Hz]
0.01/0.01
80.0
Enabled
●
/
●
−
−
●
※
[17] Commercial/inverter switching function
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0354
Output signal selection of
commercial power/inverter
switching
0: OFF, 1: Automatic switching in case of trip
2: Commercial power switching frequency setting
enabled
3: Both (1+2)
−
0
Disabled
●
/
●
●
/
●
−
●
6.16
0355
Commercial power/inverter
switching frequency
0
〜
[Hz]
0.01/0.01
60.0
Enabled
●
/
●
●
/
●
−
●
6.16
0356
Inverter side switching waiting time Model dependent
〜
10.00 [s]
0.01/0.01 See J-28 Enabled
●
/
●
●
/
●
−
●
6.16
0357
Commercial power side
switching waiting time
0.37
〜
10.00 [s]
0.01/0.01
0.62
Enabled
●
/
●
●
/
●
−
●
6.16
0358
Commercial power switching
frequency holding time
0.1
〜
10.0 [s]
0.1/0.01
2.0
Enabled
●
/
●
●
/
●
−
●
6.16
[18] PID control
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0360
Signal selection of PID control 0: PID control disabled, 1: VI/II, 2: RR, 3: RX, 4: RX2
−
0
Enabled
●
/
●
−
−
●
※
0361
Delay filter
0
〜
255
−
0
Enabled
●
/
●
−
−
●
※
0362
Proportional (P) gain
0.01
〜
100.0
0.01/0.01
0.1
Enabled
●
/
●
−
−
●
※
0363
Integral (I) gain
0.01
〜
100.0
0.01/0.01
0.1
Enabled
●
/
●
−
−
●
※
0364
PID deviation upper limit
0
〜
50 [%]
1/0.01
50
Enabled
●
/
●
−
−
●
※
0365
PID deviation lower limit
0
〜
50 [%]
1/0.01
50
Enabled
●
/
●
−
−
●
※
0366
Differential (D) gain
0.00
〜
2.55
0.01/0.01
0
Enabled
●
/
●
−
−
●
※
[19] Speed feedback/positioning control
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0367
Number of PG input pulses
1
〜
9999
1/1
500
Disabled
−
/
●
−
/
●
−
/
●
−
※
0368
Number of PG input phases
1: Single-phase input, 2: Two-phase input
−
2
Disabled
−
/
●
−
/
●
−
/
●
−
※
0369
PG disconnection detection
0: Disabled, 1: Enabled
−
0
Disabled
−
/
●
−
/
●
−
/
●
−
※
0370
Electronic gear
100 to 4000 pulses/rotation
1/1
1000
Disabled
−
−
−
/
●
−
※
0371
Position loop gain
0.0
〜
100.0
0.1/0.01
4.0
Enabled
−
−
−
/
●
−
※
0372
Positioning completion range 1
〜
4000
1/1
100
Enabled
−
−
−
/
●
−
※
0373
Frequency limit at position control 1
〜
8000 [Hz/s], 8001: disabled
1/1
800
Disabled
−
−
−
/
●
−
※
※
(Reference section): Refer to the inverter's individual manual.