MAINTENANCE MANUAL
215
STE 85357
6.3.2
Check of Safety Devices for Function
Make sure that the EMERGENCY stop pushbutton switches equipped on the teach
pendant work properly. Also make sure that the safety devices controlled by the
external operation input signals work correctly.
1)
Make sure that the EMERGENCY (emergency stop) switch provided on the
teach pendant functions properly.
a)
Turn around the key at front of controller for selecting the TEACH.
b)
Turn the EMERGENCY switch [1] clockwise and make sure that the
EMERGENCY switch [1] turns off.
c)
Press the SERVO ON switch [2] on the teach pendant to turn on the servo
power while keeping the ENABLE switch [3] at the neutral position, and make
sure that the SERVO ON LED [2] is illuminated.
Note: The servo power cannot be turned on in the TESTRUN mode.
d)
Press the EMERGENCY STOP switch [1] on the teach pendant and make
sure that the servos are turned off. The SERVO ON LED [2] goes out.
Fig. 6.4 EMERGENCY STOP switch provided on teach pendant (TSL3000E)
[1]
[2]
[3]